            Energy meter parameters:

            Meter    
             Basic parameters  Measuring range  Basic accuracy
             Voltage (V)  1.6V~1000V AC/DC  ±nominal voltage of 0.5%
             Current (A)  AC/DC  6A-300A  ±0.5%of nominal voltage
             Frequenc (Hz)  5-1K  Hz  ±10mHz
             Active power (W)  voltage range  ± 5% of power
            Power factor  0~1.0  ±0.02
             Power (Wh)  Voltage range  ±± 5% of reading
            Peak Coefficient  300KW  ±5 % 
             Voltage harmonics  inter-harmonic voltage range  accuracy ±5%
             Current harmonics  interharmonic current range  accuracy ±5%
             Voltage transients  test range ± 5% of reading
             special function    
            Number of harmonics 40 times  
             Voltage change  waveform display  
             Current change  
             Data record  6 groups per second time 30000 seconds  
             USB communication  Udisk
            •  

            • Multimeter parameters:

            • Full scale reading: 6000 count
            • DC voltage: 60.00mV, 600.0mV, 6.000V, 60.00V, 600.0V, 1000V.
            • AC voltage: 60.00mV, 600.0mV, 6.000V, 60.00V, 600.0V, 750V.
            • DC current: 600.0μA / 6000μA, 60.00mA / 600.0mA, 6.000A / 10.00A
            • AC current: 600.0μA / 6000μA, 60.00mA / 600.0mA, 6.000A / 10.00A
            • Resistance: 600.0Ω, 6.000kΩ, 60.00kΩ, 600.0kΩ, 6.000MΩ, 60.00MΩ.
            • Capacitance: 40.00nF, 400.0nF, 4.000μF, 40.00μF, 400.0μF, 4000μF
            • Diode: 0V ~ 2.0V.
            • Oscilloscope parameters:

            • Bandwidth : 20MHz
            • Vertical resolution: 8 bits
            • Input range: 10mV-5V, 100mV-50V (probe 1X10) (1,2,5 step)
            • Vertical accuracy: +/- 3%
            • Impedance: 1MΩ 25pF
            • Coupling: DC \ AC
            • Display mode: YT
            • Input voltage: 40V (x1); 400V (x10)
            • Time base range: 10ns-5s (1,2,5 steps) 100ms-5s (scan scan)
            • Storage depth: 4k (2k per channel)
            • Trigger mode: Auto, Normal, Single
            • Trigger Type: Rise, Fall
            • Automatic detection: 40Hz-50MHz
            • Measurements: peak-to-peak, duty cycle, frequency, period
          Copyright Hefei Jin Han Electronics Co., Ltd. HeFei Jinhan